Type AC - Features & Bene昀椀ts
HCF-90®
Interlocked Galvanized Steel Armor
Health Care Facilities Armored Cable
Features & Bene昀椀ts
•
Cable System. Technically equivalent and economically
superior to traditional raceway and wire installations.
•
ColorSpec® ID/Color-Trak ID System. Green galvanized steel armor with phase
ID painted directly onto the armor for added identi昀椀cation without the added
step of opening up the panel to determine circuit type.
•
Grounding. Two grounding means - (1) Armor in conjunction with 16 AWG
aluminum bond wire; (2) Green insulated copper grounding conductor.
•
Made in USA of US and/or imported materials.
Applications
•
Branch circuits and feeder wiring services in areas of patient care in hospitals,
nursing homes, outpatient facilities, dental of昀椀ces, clinics, and medical centers
(other than hazardous anesthetizing locations).
•
Can be exposed or concealed, surface mounted, embedded in plaster 昀椀nish
on brick or other masonry (except wet or damp locations), 昀椀shed or run in
air voids of masonry block or tile walls, under raised 昀氀oors, above suspended
ceilings and in other environmental air-handling spaces or any application
approved for AC cable requiring an isolated or redundant ground.
Refer to Page 14
HCF-Lite®
Interlocked Aluminum Armor
Health Care Facilities Armored Cable
Features & Bene昀椀ts
•
Cable System. Technically equivalent and economically
superior to traditional raceway and wire installations.
•
ColorSpec® ID/Color-Trak ID System. Green aluminum armor with phase ID
painted directly onto the armor for added identi昀椀cation without the added
step of opening up the panel to determine circuit type.
•
Grounding. Two grounding means - (1) Armor in conjunction with 16 AWG
aluminum bond wire; (2) Green insulated copper grounding conductor.
•
RoHS Compliant. Aluminum armored cables are RoHS compliant.
•
Made in USA of US and/or imported materials.
Applications
•
Branch circuits and feeders in areas of patient care in hospitals, nursing
homes, outpatient facilities, dental of昀椀ces, clinics, and medical centers (other
than hazardous anesthetizing locations).
•
Can be Exposed or concealed, surface mounted, embedded in plaster 昀椀nish
on brick or other masonry (except wet or damp locations), 昀椀shed or run in
air voids of masonry block or tile walls, under raised 昀氀oors, above suspended
ceilings and in other environmental air-handling spaces or any application
approved for AC cable requiring an isolated or redundant ground.